Four-way Cassette CT09F.NR0 / UUA1.UL0 1Ф

Category:

Heating capacity: 3.2 kW.

Cooling capacity: 2.5 kW.

Performance at -10°C: 2.8 kW.


  • Single-phase (1F) outdoor unit
  • Single-phase (1F) indoor unit

IMPORTANT! It is necessary to purchase accessories – panel and remote control, which are not included in the price.


 

COMBINATION
Capacity Cooling Min./Rated/Max. kW 1.5 / 2.5 / 3.2
Heating 1.8 / 3.2 / 3.7
Power Input (Set) Cooling Min./Rated/Max. kW 0.30 / 0.61 / 0.87
Heating 0.30 / 0.75 / 0.89
RunningCurrent Cooling Rated A 2.7
Heating 3.3
HONOR / COP kWh/kWh 4.10 / 4.30
SEER / SCOP kWh/kWh 6.7 / 4.0
P Design Cooling @ 35°C kW 2.5
Heating @ -10°C 2.8
Sensonal Energy Label Cooling / Heating A++ / A+
Annual Energy Consumption Cooling / Heating kWh 131 / 980
Dehumidification Rate l/h 0.63
ODU Sound Pressure Level Cooling / Heating Rated dB(A) 49 / 52
ODU Sound Power Level Cooling Rated dB(A) 65
Piping Connections Liquid Outer Dia mm (inch) ø 6.35 (1/4)
Gas Outer Dia mm (inch) ø 9.52 (3/8)
Connection Method Flared
Operation Range (Outdoor) Cooling My. / Max. °C – 15 / 50
Heating – 20 / 18
INDOOR CT09F.NR0
Power Supply ø / V / Hz 1 / 220-240 / 50
Power Input Min. / Nom. / Max. IN 26 / 22 / 19
Air Flow Rate H / M / L m3/min 8.5 / 7.0 / 6.0
Dimensions Body W x H x D mm 570 x 214 x 570
Weight Body kg 12.4
Sound Pressure Level Cooling H / M / L dB(A) 36 / 33 / 30
Sound Power Level Cooling Max. dB(A) 52
Piping Connections Drain O.D / I.D mm ø 32.0 / 25.0
Panel Model PT-QAGW0
OUTDOOR UUA1.UL0
Power Supply ø / V / Hz 1 / 220-240 / 50
Circuit Breaker Min. A 15
Power Supply Cable (included Eart) No. x mm2 3C x 1.5
Dimensions Net W x H x D mm 770 x 545 x 288
Weight Net kg 33.3
Compressor Type Twin Rotary
Refrigerant Type R32
Fan Air flow Rate Rated m3/min x No 28×1
Total Piping Length My. / Max. m 5 / 30
Piping Elevation IDU-ODU Max. m 30