Indoor unit HN1610H NK3
Operating mode (outgoing water) Heating, DHW My. ~ Max. °C DB 25 – 80
Compressor Type Hermetic Motor Compressor
Model Model × No. EPT525MBA × 1
Engine type Scroll
Working volume cm3/Rev. 52,5
Heat exchanger Water circle Type Brazed Plate HEX
Quantity 1
Number of slats YES 76
Water volume 1,0
Refrigeration circuit Type Brazed Plate HEX
Quantity 1
Number of slats YES 50
Refrigerant Type R134a
GWP (global warming potential) 1 430,0
Loaded quantity g 1 800
t-CO2 eq. 2,574
Control Electronic Expansion Valve
Refrigerant oil Type FVC68D
Loaded quantity cc × No. 1 300
Filter Connection size 28 mesh
Material Stainless Steel
Water flow rate (Min. ~ Max.) l/min 46 (15 – 70)
Hydraulic losses kPa 30,68
Flow Factor (Kv) 4,98
Components of the water cycle Flow Switch
Pipe connections Water circle Login mm(Inch) Male PT 25(1)
Exodus mm(Inch) Male PT 25(1)
Refrigeration circuit Gas mm(Inch) F 15.88 (5/8)
Liquid mm(Inch) F 9.52 (3/8)
Sound power Heating
(fan off)
Nominally dB(A) 58
Heating
(incl. fan)
Nominally dB(A) 63
Sound pressure (at 1m) Heating Nominally dB(A) 50
Dimensions Body W × H × D mm 520 x 1,080 x 330
With packaging W × H × D mm 682 x 1,168 x 423
Weight Body kg 84,0
With packaging kg 92,0
Electrical specifications HN1610H NK3
Power supply V, Ø, Hz 220-240, 1, 50
Maximum power IN 4 750
Maximum operating current A 20,2
Wiring Power cord (with grounding) No × mm2 3 × 4.0 (H07RN-F)
Communication Cable (included Earth) No × mm2 2 x 1.0~1.5 (VCTF-SB)

 

Nominal capacity outdoor unit HU161HA U33
Category Outside temp. (°C)
DB / WB
Leaving water temp. (°C)
Capacity 7 / 6 35 kW 16,0
55 kW 14,0
COP 7 / 6 35 In/In 3,27
55 In/In 2,78
SCOP (Low Temp. Temperate Climate) 3,23
SCOP (High Temp. Temperate Climate) 3,01
Water flow rate (at outlet water temp. 35 ℃) 46,0
Outdoor unit – specifications HU161HA U33
Operating mode (outdoor temperature) Heating My. ~ Max. °C DB -25 ~ 35
Compressor Type Hermetic Sealed Scroll
Model Model × No. RJB036MAA × 1
Engine type BLDC
Working volume cm3/Rev. 31,6
Refrigerant Type R410A
GWP (Global Warming Potential) 2 078,5
Loaded quantity g 3 800
t-CO2 eq. 7,933
Control Electronic Expansion Valve
Refrigerant oil Type FVC68D
Loaded quantity cc × No. 1 100
Pipe connections Gas mm(Inch) F 15.88 (5/8)
Liquid mm(Inch) F 9.52 (3/8)
Pipe length Standard m 7,5
Max. m 50
Pipe leveling Max. m 30
Pipeline length without recharge m 7,5
Additional charging g/m 40
Heat exchanger Type Fin & Tube
Quantity YES 2
Specification Row YES 2
Column YES 32
FPI YES 14
Fan Type Propeller
air flow rate Rated m3/min × No. 60.0 × 2
Fan motor Type BLDC
Exodus W × No. 124 × 2
Electrical specifications HU161HA U33
Power supply V, Ø, Hz 220-240, 1, 50
Maximum input power IN 4 445
Maximum operating current A 18,9
Peak field at work A
Operating current (rated) A 8,4
Wiring Power cable (with grounding, H07RN-F) No × mm2 3 × 4.0 (H07RN-F)
Technical specifications HU161HA U33
Sound power level Heating Rated dB(A) 63
Sound power level at 1 meter Heating Rated dB(A) 55
Dimensions Body W × H × D mm 950 X 1,380 X 330
With packaging W × H × D mm 1,140 X 1,553 X 466
Weight Body kg 89,0
With packaging kg 102,0