| Heating (A7/W35) | 6.2 kW |
| Electrical P absorbed (A7/W35) | 1,24 kW |
| – COP (A7/W35) | 5 |
| Heating (A7/W45) | 6.35 kW |
| – P electrical absorbed (A7/W45) | 1,69 kW |
| – COP (A7/W45) | 3,75 |
| Heating (A7/W55) | 6 kW |
| – P electric absorbed (A7/W55) | 2 kW |
| – COP (A7/W55) | 3 |
| Cooling (A35/W18) | 6.55 kW |
| – P electric absorbed (A35/W18) | 1,34 kW |
| – EER (A35/W18) | 4,9 |
| Racer (A35/W7) | 7 kW |
| – P electric absorbed (A35/W7) | 2,33 kW |
| – EER (A35/W7) | 3 |
| Seasonal efficiency class LWT 35C: | A+++ |
| Seasonal efficiency class LWT 55C: | A++ |
| Tip | phase |
| Power supply | 230/50 V/Hz |
| Compressor | BLDC inverter |
| R32 refrigerant factory charge | 1,5 kg |
| Sound noise EN12102-1 | 58 dB/A |
| Beach outside temperature- Cooling | 5~43 °C |
| Beach outside temperature – Heating | -25~35 °C |
| Outdoor temperature beach – Domestic hot water | -24~43 °C |
| External unit net mass | 58 kg |
| External unit dimensions (wxhxh) | 1008x426x712 mm |
| Power supply | 230/50 V/Hz |
| Circulation pump | de tip inverter |
| Maximum pressure | 9 mCA |
| Hydraulic connections | 1 ” |
| Electrical resistance (back-up) | 3 kW |
| Beach water temperature – Cooling | 5~25 °C |
| Expansion vessel (Volume) | 8 l |
| Beach water temperature – Heating | 25~65 °C |
| Beach water temperature – Domestic Hot Water | 30~60 °C |
| Sound noise EN12102-1 | 38 dB/A |
| Internal unit dimensions (wxhxh) | 420x790x270 mm |
| Internal unit net mass | 37 kg |
Air-water heat pump R32 split 6kW (1×230) HYUNDAI [HYHA-V6W/D2N8-B + HYHA-A60/CD30GN8-B]
SPLIT air-water heat pumps
– freon ecologic R32
– compressor BLDC Inverter high performance system
– extremely silent operation
– fully equipped with circulation pump, expansion vessel, safety valve
– integrated WIFI function with remote control (smartphone)
– operation up to -25 degrees C
– heating agent temperature up to 65 degrees C
– operation in cascade up to 6 units
– fast hot water preparation function
– anti-legionela function (boiler disinfection)
– possibility to control 2 heating zones