| Technical Specification | OAT | LWT | Indoor Unit | HN0913T NK0 | |
| Outdoor Unit | HU051MR U44 | ||||
| Nominal Capacity | Heating | 7°C | 35°C | kW | 5.50 |
| 7°C | 55°C | 5.50 | |||
| Cooling | 2°C | 35°C | 3.30 | ||
| 35°C | 18°C | 5.50 | |||
| 35°C | 7°C | 5.50 | |||
| Nominal Power Input | Heating | 7°C | 35°C | kW | 1.12 |
| 7°C | 55°C | 2.4 | |||
| Cooling | 2°C | 35°C | 0.94 | ||
| 35°C | 18°C | 1.20 | |||
| 35°C | 7°C | 1.96 | |||
| COP | Heating | 7°C | 35°C | In/In | 4.90 |
| 7°C | 55°C | 2.70 | |||
| 2°C | 35°C | 3.52 | |||
| HONOR | Cooling | 35°C | 18°C | In/In | 4.60 |
| 35°C | 7°C | 2.80 | |||
| Operation Range (Outdoor Temp.) | Heating | My. ~ Max. | My. ~ Max. | °C DB | -25 ~ 35 |
| Cooling | My. ~ Max. | My. ~ Max. | °C DB | 5 ~ 48 | |
| Compressor | Type | – | Hermetic Sealed Scroll | ||
| Refrigerant | Type | – | R32 | ||
| GWP (Global Warming Potential) | – | 675 | |||
| Precharged Amount | q | 1,5 | |||
| t-CO2 eq | – | 1.013 | |||
| Piping Connections | Outer Diameter | Liquid | mm (inch) | Ø 9.52 (3/8) | |
| Gas | mm (inch) | Ø 15.88 (5/8) | |||
| Length | |||||
| Standard | m | 5 | |||
| Level Difference | Max. | m | 50 | ||
| Chargeless-Pipe Length | Max. | m | 30 | ||
| Additional Charging Volume | – | m | 10 | ||
| – | g/m | 40 | |||
| Rated Water Flow Rate (at LWT 35°C) | ℓ/min | 15.4 | |||
| Sound Power Level | Heating | Rated | dB(A) | 60 | |
| Sound Pressure Level (at 1m) | Heating | Rated | dB(A) | 52 | |
| Dimensions | Unit | W x H x D | mm | 950 × 834 × 330 | |
| Weight | Unit | kg | 60.0 | ||
| Exterior | Color / RAL Code | – | Warm Gray / RAL 7044 | ||
| Electrical Specification | Outdoor Unit | HU051MR U44 | |||
| Power Supply | Voltage, Phase, Frequency | – | V, Ø, Hz | 220-240, 1, 50 | |
| Rated Running Current | Cooling | A | 5.0 | ||
| Heating | A | 5.3 | |||
| Wiring Connections | Power Supply Cable (included earth, H07RN-F) | mm² x cores | 4.0 x 3C | ||
| Technical Specification | Indoor Unit | HN0913T NK0 | |||
| Operation Range | Heating | My. ~ Max. | °C | 15 ~ 65 | |
| (Leaving Water Temp.) | |||||
| Cooling | My. ~ Max. | 5 ~ 27 (16 ~ 27) 1) | |||
| Domestic Hot Water | My. ~ Max. | 15 ~ 80 2) | |||
| Domestic Hot Water Tank | Volume | ℓ | 200 | ||
| Material | – | Duplex Stainless Steel | |||
| Internal Thermal Protect Limit | °C | 85 | |||
| Main Water Pump | Model | – | Grundfos UPM3K 20-75 CHBL | ||
| Flow Sensor | Measuring Range | My. ~ Max. | ℓ/min | 5 ~ 80 | |
| Water Pressure Sensor | Measuring Range | My. ~ Max. | bar (G) | 0 ~ 20 | |
| Expansion Vessel (Heating Circuit) | Volume | ℓ | 8 | ||
| Safety Valve | Heating Circuit | Upper Limit | bar | 3 | |
| DHW Circuit | Upper Limit | bar | 10 | ||
| Piping Connections | Refrigerant Circuit | Liquid (outside diameter) | mm (Inch) | Ø 9.52 (3/8) | |
| Gas (outside diameter) | mm (Inch) | Ø 15.88 (5/8) | |||
| Water Circuit | |||||
| Inlet | Inch | Female G1″ according to ISO228-1 (parallel pipe threads) | |||
| Outlet | Inch | Female G1″ according to ISO228-1 (parallel pipe threads) | |||
| DHW Tank Water Circuit | |||||
| Cold Inlet | Inch | Female G1″ according to ISO228-1 (parallel pipe threads) | |||
| Hot Outlet | Inch | Female G1″ according to ISO228-1 (parallel pipe threads) | |||
| Recirculation | Inch | Female G1″ according to ISO228-1 (parallel pipe threads) | |||
| Sound Power Level | Heating | Rated | dB(A) | 42 | |
| Dimensions | Unit | W × H × D | mm | 600 × 1,750 × 660 | |
| Weight (without water) | Unit | kg | 118 | ||
| Exterior | Color / RAL Code | – | White / RAL 9016 | ||
| Electrical Specification | Indoor Unit | HN0913T NK0 | |||
| Wiring Connections | Power and Communication Cable (Included Earth, H07RN-F) | mm² x cores | 0.75 x 4C | ||
| Electric Heater | Type | – | Sheath | ||
| No. of Heating Coil | YES | 2 | |||
| Capacity Combination | kW | 3 | |||
| Heating Step | Step | 1 | |||
| Power Supply | V, Ø, Hz | 220-240, 1, 50 | |||
| Wiring Connections Power Supply Cable (Included Earth, H07RN-F) | mm² x cores | 1.5 x 3C | |||
| Rated Current | A | 13.0 | |||
LG THERMA V Split Integrated Water Tank HU051MR.U44 / HN0913T.NK0
5 years full warranty
- Quick and easy installation
- Integration of a DHW tank and hydraulic component
- Integrated 3kW backup heater and expansion tank for heating
- Improved installation flexibility
- Refrigerant pipes connect IDU and ODU
- Light weight and compact size indoor unit
- Max. 50 m refrigerant piping and 3-way pipe connection available
- High efficiency and wide operating range
- R32 Low GWP refrigerant
- SCOP up to 4.65 / 3.12 (low temperature / medium temperature application): A+++ / A++
- Water heating efficiency 133% (5.7kW, L profile) / 140% (9kW, XL profile): A+
- COP up to 4.90 (outdoor air 7°C / leaving water 35°C) Leaving water temperature up to 65°C
Possibility to add additional accessories:
- Wi-Fi modem PWFMDD200 – enables control of the machine via a mobile device.